Design & Experimental Investigation of XY Compliant Mechanism for Precision Applications

Main Article Content

Article Sidebar

Published Sep 14, 2021
Shrishail Sollapur

Abstract

A XY compliant mechanism is designed for the precision application with higher range, precision and accuracy. In earlier work many researchers have used different methods to design compliant mechanism. In this paper XY positioning stage is designed using blocks method. However, the model is monolithic in nature to avoid joints. By using wire EDM the XY model is manufactured. Voice Coil actuators are used for the displacement which give larger range. Analytical modeling is carried out and is validated with MATLAB results. Finally, experimentation is done for performance analysis. The XY model gives ±6mm with motion direction. XY model evaluates both static and dynamic performances.

How to Cite

Sollapur, S. (2021). Design & Experimental Investigation of XY Compliant Mechanism for Precision Applications. SPAST Abstracts, 1(01). Retrieved from https://spast.org/techrep/article/view/344
Abstract 16 |

Article Details

References
[1] Shrishail B Sollapur, Dr. M S Patil and Dr. S P Deshmukh, “Experimental Investigation of High Precision XY Mechanism”, International Journal of Mechanical Engineering and Technology, 9(5), 2018, pp.43–50. http://www.iaeme.com/IJMET/issues.asp?JType=IJMET&VType=9&IType=5
[2] Jaeyoo Yoo, Sungho Park, Hyuk Lee, Sangsub Jeong, New Capacity Modulation Algorithm for Linear Compressor, International Compressor Engineering Conference at Purdue, July 12-15, 2010. https://citeseerx.ist.psu.edu/viewdoc/download?doi=10.1.1.982.8501&rep=rep1&type=pdf
[3] B Sollapur Shrishail, P Deshmukh Suhas. “XY scanning mechanism: a dynamic approach”. Int. J. Mech. Eng. And Rob. Res, 3 (2014), 140-154., http://www.ijmerr.com/uploadfile/2015/0409/20150409113246805.pdf
[4] Shrishail Sollapur, M S Patil , S P Deshmukh , “Design and Development Aspects of Flexure Mechanism for High Precision Application”, AIP Conference Proceedings 1943, 020023 (2018); doi: 10.1063/1.5029599, 2018.
[5] S. Awatar, Synthesis and analysis of parallel kinematic xy flexure mechanism, PhD Thesis, Massachusetts Institute of Technology, Cambridge, MA, see also URL http://web.mit.edu/~shorya/www/PHD/Thesis (May 2004).
[6] Hwa Soo Kim, Young Man Cho, Design and modeling of a novel 3-DOF precision micro-stage, Mechatronics 19 (2009) 598–608. https://doi.org/10.1016/j.mechatronics.2009.01.004
[7] Yangmin Li, Qingsong Xu, Modeling and performance evalutrion of a flexure-based XY parallel micromanipulator, Mechanism and machine Theory, 44 (2009) 2127-2152; https://ur.booksc.eu/book/8731084/4b2cd9
[8] Dongwoo Kang, Kihyun Kim, Dongmin Kim, et al. Optimal Design of High Precision XY-Scanner with Nanometer- Level Resolution and Millimetre-Level Working Range. Mechatronics. 2009; 19: 562–570p. https://doi.org/10.1016/j.mechatronics.2009.01.002
[9] Shorya Awtar, Slocum Alexander H. Topology Evolution of High Performance XY Flexure Stages. Precis Eng. 2007. http://hdl.handle.net/1721.1/17945
[10] Shrishail B Sollapur, Dr. M S Patil and Dr. S P Deshmukh, “Position Estimator Algorithm Implementation on Precision Applications”, Materials Today: Proceedings Volume 24, Part 2, 2020, Pages 333-342, https://doi.org/10.1016/j.matpr.2020.04.283
Section
GE4- Mechanical Engineering